Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block

₹0.00

Genuine Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block (Bulletin 100-C IEC 4-Pole Magnetic Contactor, 4 Main N.O. Poles, 9A AC-3 / 32A AC-1, Electronic/DC Coil + 100S-F Front Auxiliary Block) in ready stock at Fine Oilfield & Marine Supply, Bhavnagar, India. Ready for worldwide shipping.

Available in store

Choose Quantity
Category:

The Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block (Rockwell Automation / Allen-Bradley Bulletin 100-C IEC 4-Pole Electronic-Coil Magnetic Contactor — Catalog Number: 100-C09E*400, Fitted with Front-Mounted Bulletin 100S-F Safety / Mechanically Linked Auxiliary Contact Block) is a complete industrial and marine-grade 4-pole power switching assembly rated at 9A (AC-3) / 32A (AC-1). Engineered with 4 main normally open (4 N.O.) power poles, a low-consumption electronic/DC control coil (“E” coil series), and a front-mounted 100S-F auxiliary contact block for reliable PLC and safety-circuit feedback, this unit is available in ready stock at Fine Oilfield & Marine Supply, Bhavnagar, Gujarat, India.

Technical Specifications of Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block
• Brand: Allen-Bradley (Rockwell Automation — Bulletin 100-C / 100S IEC Contactors & Auxiliaries)
• Contactor Catalog / Part Number: 100-C09E*400 (Base Frame 100-C09, Electronic/DC “E” Coil Series, 4 Main N.O. Power Poles — Check Side Label for Exact Coil Code)
• Mounted Auxiliary Contact Block: Allen-Bradley Bulletin 100S-F Front-Mounted Safety / Mechanically Linked Auxiliary Contact Block (e.g., 100S-FA02 / 100S-FA11 / 100S-FA20 / 100S-FA22 — Check Top Block Marking)
• Main Power Pole Configuration: 4 Poles — 4 Normally Open (4 N.O. Main Power Contacts: 1-2, 3-4, 5-6, 7-8)
• Rated Operational Current (AC-3, 400V): 9 A (4 kW Three-Phase Motor Rating @ 400V AC / 7.5 HP @ 460V–575V AC)
• Rated Thermal Current (AC-1, 690V): 32 A (25 A Enclosed — Ideal for 4-Pole Resistive Heating & Power Isolation Loads)
• Rated Operational & Impulse Voltage: Up to 690V AC (IEC) / 600V AC (UL/CSA), Rated Impulse Withstand Voltage Uimp = 6 kV / 8 kV
• Control Coil Voltage Variants (“E*” Electronic/DC Coil Code): Low-Hold-Power Electronic Coil (Commonly 24V DC “EJ”, 48–72V DC “EW”, or 110–125V DC “ED” — Verify Side Coil Code)
• Auxiliary Contact Rating (100S-F Block): A600 / Q600 Pilot Duty, IEC 60947-5-1 Mechanically Linked / Mirror Contacts (Gold-Plated / Bifurcated Low-Level Switching Capable)
• Terminal & Mounting Standard: Finger-Safe IP2X Screw Clamp Terminals; 35 mm DIN-Rail Snap-On or Direct Panel Screw Mounting
• Supply Condition: Visually Inspected, All 4 Main Poles & 100S-F Auxiliary Contacts Continuity, Electronic Coil Resistance & Magnetic Pull-In Bench Tested, Ready for Immediate Dispatch

Key Features & Operational Benefits
The Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block pairs a low-wattage electronic/DC coil (“E” series) with four full-rated 32A (AC-1) power poles, drastically reducing control power supply load and cabinet heat dissipation in 24V DC or 110V DC shipboard control panels. The pre-installed Bulletin 100S-F front-mounted auxiliary block provides positively guided, mechanically linked feedback contacts (with high-visibility red/yellow safety housing) for dependable PLC status monitoring and safety interlock verification.

Marine, Offshore & Industrial Applications
Manufactured to meet strict international marine, machinery safety, and switchgear standards (IEC/EN 60947-4-1, IEC/EN 60947-5-1, cULus / UL Listed, CSA, CE, and major marine classification society approvals including ABS, DNV GL, Lloyd’s Register, Bureau Veritas, and ClassNK), the Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block is widely deployed across:
• Shipboard Engine Room purifier fuel/lube oil heater banks, 24V DC / 110V DC PLC-controlled auxiliary panels, and 4-pole power isolation circuits
• Container ships, VLCC/ULCC crude oil tankers, chemical & product tankers, LNG/LPG carriers, bulk carriers, and offshore support vessels (OSVs)
• Offshore oil & gas drilling platforms, FPSO safety-interlocked utility skids, emergency shutdown (ESD) relay panels, and jack-up rigs
• Industrial motor control centers (MCCs), resistive heating panels, automated packaging machinery, and safety-monitored PLC control cabinets

Installation & Maintenance Guidelines
Before installing or replacing the Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block, isolate and lock out all main four-pole power feeds and DC/electronic control coil circuits and confirm zero voltage across power terminals (1/L1, 3/L2, 5/L3, 7/L4), coil terminals (A1/A2), and the 100S-F auxiliary block. Verify polarity if required on DC coil variants and confirm the exact voltage printed on the side label, clip the assembly firmly onto a 35 mm DIN rail, ensure the 100S-F front auxiliary block is securely latched onto the contactor actuator carrier, torque all screw terminals to Rockwell Automation specifications, and verify simultaneous switching of all 4 N.O. main poles and 100S-F auxiliary contacts prior to energizing live load circuits.

Why Source From Fine Oilfield & Marine Supply?
Located in Bhavnagar, Gujarat, India—one of the world’s premier sourcing hubs for marine switchboard equipment and industrial automation spares—Fine Oilfield & Marine Supply maintains ready stock of genuine Allen-Bradley (100-C09, 100-C12, 100-C16, 100-C23, 100-C30, 100-C37, 100-C43, 100-C60, 100S safety contactors, and 100-FA / 100S-F auxiliary contact blocks), ABB, Siemens, Schneider Electric, Telemecanique, and Mitsubishi switchgear. Every Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block undergoes visual contact/latch inspection and live bench coil pull-in testing before dispatch.

We provide fast worldwide express delivery via DHL, FedEx, air cargo, and sea freight to the UAE, Oman, Saudi Arabia, USA, Europe, Kazakhstan, Singapore, and international dry-docks/ports. Visit https://fineoilfield.com/ to browse our complete inventory of Allen-Bradley contactors, auxiliary blocks, and marine electrical switchgear.

Frequently Asked Questions (FAQs)
Q1: What is the specification of the Allen-Bradley 100-C09E*400 Contactor With 100S-F Auxiliary Contact Block?
It combines a 4-pole (4 N.O.) 9A AC-3 / 32A AC-1 Bulletin 100-C contactor equipped with a low-consumption electronic/DC control coil (“E” code) and a front-mounted Bulletin 100S-F mechanically linked safety auxiliary contact block.

Q2: How can I confirm the exact “E*” coil voltage and 100S-F contact configuration (NO/NC) or request an urgent quote from Fine Oilfield & Marine Supply?
Email sales@fineoilfield.com or call/WhatsApp +91 9824579191 for real-time close-up photos of the side coil voltage label, top 100S-F auxiliary block markings, and same-day DHL/FedEx shipping quotes.